The state of ladder status is now saved for each comm. path.
Added the following DX zoom screens: XMIT, Compact STAT, Micro STAT, Momentum STAT.
Added support for TCOP modules ADU210, ADU214, ADU257, DAU211, 212, 220, 250, 252, 253, and 292, KOS260-24, KOS260-64.
Solutions
Corrected wrong port type saved with file save through TCP/IP to SA85 Bridge.
Corrected problem where the JSR did not show constants as a valid type for top node.
Corrected item where Site License window was coming up for the Server after PLC WorkShop was already executed.
Corrected problem where we were unable to load an EXE loadable to PLC program.
Corrected problem in the TCP setup, modifying the retries or time out would give Port range error.
Corrected problem where the column display in the Cross Reference was sized incorrectly, too small, when doing a new and sizing the window and rebuilding XREF.
Corrected problem where sizing the Cross Reference Window to about two columns was causing a divide by zero GPF.
Corrected problem where in continuous mode the Append or Insert network was not working properly for the End of Segment.
Corrected problem when connected with the TCP/IP, and with SA85, if you do a save, it would default the filename as the description name that you had for the TCP/IP address.
Corrected problem that Cut by Parts was allowed online. This caused the node editor to malfunction and possibly GPF.
Corrected problem where Import of DOS PGR’s was not bringing in the Headers.
Corrected problem of Merge not merging the Headers.
Fixed memory leaks in Status and Powerflow which could have caused a GPF.
Corrected problem where Import FTK with 1 tag, and Edit the doc gave GPF.
Corrected problem when trying to import doc of an FMD, it gave error doing shared Doc with object open.
Corrected in PCOP, where you could not clear Specific IO or Global IO devices above device 2.
Corrected Loadable screen online: The File Contents always displayed in WORDS and the Current Program showed in BYTES.
Corrected problem where loadables larger then 50K would cause an overwrite in the configuration code.
Corrected problem where Compare of loadables did not work online.
Corrected problem where number nodes of logic used by an EXE loadable was only 1/2 of what it should have used.
Corrected problem that TCP/IP to Modbus Plus bridge did not work. SGATE bridge software needed to be upgraded. Also a minor change was done to server to communicate to multiple PLC’s better.
Corrected problem where the Latch Coil attaches the picture for a falling one shot on the cursor.
Corrected GPF that occurred Online by dropping a Latch coil on top of a regular existing coil, and clicking off of it.
Corrected problem where changing PLC type from Quantum to A145 caused the TCOP to get mixed up and unable to add modules.
Corrected problem where import of Doc only, of a PGR, was not bringing in the headers.
Corrected problem where opening a PGR file and doing print, would give error “Please enter a 0X register range from 1 to 0”.