Users can now import ModSoft version 2.62 project files into WorkShop while offline.
A more informative warning message appears when making changes to PLC Configuration.
Selecting the Simulator toolbar icon in WorkShop when Simulator is running will return focus to the Simulator application.
Data displayed in the Data Window can now be printed directly from the Data Window.
The Data Window now displays 16-bit binary values in two groups of 8 bits instead of one 16-bit string.
Communications settings can now be stored with the program file.
WorkShop now accepts communications settings from FTVersionTrak when an FTVersionTrak user requests to edit or view a WorkShop file with specified communications settings.
Solutions
Selecting a Flush Buffer in the ASCII Message Editor now enables the proper text box.
Enabling a non-forced contact no longer causes other forced contact to become unforced.
Zooming into analog input module 140 ACI 051 00 now displays the correct data format.
Modbus Comm Network Access now correctly retains modified settings for serial ports.
WorkShop no longer reports an inaccurate memory allocation error when performing a logic search while online.
WorkShop no longer closes unexpectedly when Cross Referencing by a 6x register start address when the program does not contain any 6x registers.
Text containing spaces that has been copied from the Windows clipboard can no longer be pasted as a documentation tag.
PCFL Analog Input Register Flag values are now entered as one word instead of two words.
Importing documentation from a *.csv file when the Address Display Size is set to 5 digits now properly updates all imported documentation.
Attempting to add an I/O module in Traffic Cop that exceeds the maximum number of I/O points available for the PLC now displays the proper error message.
Leaving the ladder cursor on an instruction address for an extended period of time no longer causes the address to change unexpectedly.
WorkShop now saves and restores the maximized or minimized state of the logic window.
I/O modules 170 ADO 830-30, 170 AMM 110-30, and 170 ADM 850-10 are now supported in Traffic Cop.
FasTrak Security no longer allows a program file to be saved when exiting the program if security is configured to disallow saving changes to the program.
Performing a search while online no longer returns a “logic store record not found” error when encountering a blank segment.
All documentation now prints properly when sorting by tag or description.