Features

  • Users can now import ModSoft version 2.62 project files into WorkShop while offline.
  • A more informative warning message appears when making changes to PLC Configuration.
  • Selecting the Simulator toolbar icon in WorkShop when Simulator is running will return focus to the Simulator application.
  • Data displayed in the Data Window can now be printed directly from the Data Window.
  • The Data Window now displays 16-bit binary values in two groups of 8 bits instead of one 16-bit string.
  • Communications settings can now be stored with the program file.
  • WorkShop now accepts communications settings from FTVersionTrak when an FTVersionTrak user requests to edit or view a WorkShop file with specified communications settings.

Solutions

  • Selecting a Flush Buffer in the ASCII Message Editor now enables the proper text box.
  • Enabling a non-forced contact no longer causes other forced contact to become unforced.
  • Zooming into analog input module 140 ACI 051 00 now displays the correct data format.
  • Modbus Comm Network Access now correctly retains modified settings for serial ports.
  • WorkShop no longer reports an inaccurate memory allocation error when performing a logic search while online.
  • WorkShop no longer closes unexpectedly when Cross Referencing by a 6x register start address when the program does not contain any 6x registers.
  • Text containing spaces that has been copied from the Windows clipboard can no longer be pasted as a documentation tag.
  • PCFL Analog Input Register Flag values are now entered as one word instead of two words.
  • Importing documentation from a *.csv file when the Address Display Size is set to 5 digits now properly updates all imported documentation.
  • Attempting to add an I/O module in Traffic Cop that exceeds the maximum number of I/O points available for the PLC now displays the proper error message.
  • Leaving the ladder cursor on an instruction address for an extended period of time no longer causes the address to change unexpectedly.
  • WorkShop now saves and restores the maximized or minimized state of the logic window.
  • I/O modules 170 ADO 830-30, 170 AMM 110-30, and 170 ADM 850-10 are now supported in Traffic Cop.
  • FasTrak Security no longer allows a program file to be saved when exiting the program if security is configured to disallow saving changes to the program.
  • Performing a search while online no longer returns a “logic store record not found” error when encountering a blank segment.
  • All documentation now prints properly when sorting by tag or description.