Features
- Headers may now be imported and exported for the “Delimited Documentation Text” format.
- The All Headers dialog now features Delete, Insert, Cut, Copy, and Paste functionality to quickly and easily reassign header information to other networks.
- Column widths in the Data Window are now saved with the program.
Solutions
- A network can now be added to an empty segment while in continuous mode.
- Performing a block move online when the high address in the move range is lower than the address of a used coil in the program no longer causes WorkShop to return a “Coil is already in use” error for the unused coil addresses specified within the range.
- Saving a program that contains an empty first segment while online with the PLC no longer results in an error when the program is opened offline.
- Added support for the Momentum I/O Bus module ARM 370 30.
- The FTVersionTrak Connect to Repository toolbar and menu item are no longer enabled when you connect directly to a PLC.
- Confirming changes made during a Replace Table function no longer causes WorkShop to unexpectedly close.
- A warning message properly appears when attempting to open an FTVersionTrak-tracked file that has been deleted or destroyed in the FTVersionTrak repository.
- Files loaded into the simulator can now be cross referenced properly.
- Segment headers that are deleted outside of the Segment Header Input dialog are now properly updated.
- The TAND function is now properly recognized as part of a network equation.
- Clicking the Help button in the Replace Table dialog now displays the appropriate help topic.
- Performing a fill in the data window in insert mode no longer overwrites the selected cell.
- Losing communication to the PLC during a search now correctly reports a response timeout.
- Losing communication to the FTVersionTrak database now correctly reports disconnection and no longer results in an error.
- Logging out of the PLC no longer has the potential to cause deadlock.
- Powerflow and ladder status are no longer turned off and disabled after an attempt to edit a ladder cell fails.
- Attempting to cancel a required checkout while working with FTVersionTrak now properly cancels the action.
- Attempting to compare a WorkShop file with unsaved changes using FTVersionTrak now properly displays changes when saved.
- Errors that occur while online in the data window as a result of an update from the communications server no longer have the potential to cause deadlock.
- Ladder status properly deactivates when saving to a program while online.
- Intermittent undefined server error messages no longer appear when ladder status is switched off.
- A network may now be properly be added to an empty segment while in continuous mode.
- Attempting to go to an empty segment from the All Headers dialog no longer automatically creates an empty network.
- Attempting to view a single segment from the All Headers dialog when no segments are selected no longer causes an error.
- Attempting to close a file containing network header at maximum size no longer causes an application error.
- Attempting to import headers when a network or segment header has been previously replaced by an empty header no longer causes the import to fail.