- Corrected problem of a keyword search in the Documentation Window returning an incorrect address when the documentation is not sorted by address.
- Corrected use of hotkeys when adding N/O or N/C Contacts or Coils in ladder after entering an address.
- When programs for different PLC types are open, and floating toolbars are used, the appropriate instruction set within the floating toolbar now displays when focus is changed among logic windows.
- No longer limit the Read and Write Reference Remote addresses in the Edit I/O Scanner Transaction dialog to the configured address limits of the local PLC.
- Corrected problem of all segments not printing if Network Number Mode in Program Setup is not set to Continuous or logic windows are not open for each segment.
- The Module Zoom for DAU 2×2 screen now lists an option of Unipolar 15 Bit+Sign.
- The Floating Documentation Window now hides/appears when its Application Setup setting is changed while no program is open.
- The Floating Documentation Window and Toolbars now appear above the Status Bar.
- Import dialog now accepts manually entered file names.
- When the ladder cursor is placed on a constant, documentation in the Floating Documentation Window is now cleared.
- Improved parameter validation when 5-digit constants are entered under 5-digit address display size.
- Corrected problem, which prevented security administrators from modifying FasTrak Authentication Security under international versions of Windows.
- The following hotkeys were added to dialogs: Alt-O (OK), Alt-C (Cancel, Close), Alt-L (Clear), and Alt-H (Help).
- Reduced time to save programs via TCP/IP.
- Corrected problem with minimized windows being forced below bottom edge of the WorkShop window.
- When saving a file, original case of the entered file name is now retained.
- Corrected problem that occurred when loadables, which exist in ladder, are deleted.
- Corrected problem of incorrect print range settings being retained when the last network of a program is deleted.
- Revised error message generated within Print dialogs when network count mismatches.
- Analog and discrete input and output address types can now be used on Modules BKF201 and BDF202 of a 984-275E Compact.
- Improved error message generated during Lines per Page validation in the Page Setup dialog when the value is less than 15.
- Corrected problem of documentation not updating in the Data Window after editing using Ctrl-L.
- ProWORX.FIL record types are now imported as tags into WorkShop address documentation. Tags are exported as records into ProWORX.FIL files.
- Improved dialog message regarding the Cross Reference table not being up to date.
- Reinstalling WorkShop now replaces server DLLs, which were manually deleted from the system directory.
- Corrected problem when launching WorkShop by double-clicking a program file.
- Corrected problem in the Documentation Window with displaying the wrong address in the Edit Documentation dialog via the Modify Doc. right-click menu option.
- Corrected problem with the Data Window going blank when canceling a close program command.
- Corrected error message generated when maximum rows exceeded within the Data Window using the Fill dialog.
- Corrected problem with 1..5V or 4..20mA setting in a 170 AAI 030 00 Momentum Module Zoom.
- All 8 channels are now available when 170 AAI 030 00 Momentum modules are configured in Momentum I/O drops.
- Corrected problem of files not merging properly in some PLC types when TCOP is included.