Features
- The state of ladder status is now saved for each comm. path.
- Added the following DX zoom screens: XMIT, Compact STAT, Micro STAT, Momentum STAT.
- Added support for TCOP modules ADU210, ADU214, ADU257, DAU211, 212, 220, 250, 252, 253, and 292, KOS260-24, KOS260-64.
Solutions
- Corrected wrong port type saved with file save through TCP/IP to SA85 Bridge.
- Corrected problem where the JSR did not show constants as a valid type for top node.
- Corrected item where Site License window was coming up for the Server after PLC WorkShop was already executed.
- Corrected problem where we were unable to load an EXE loadable to PLC program.
- Corrected problem in the TCP setup, modifying the retries or time out would give Port range error.
- Corrected problem where the column display in the Cross Reference was sized incorrectly, too small, when doing a new and sizing the window and rebuilding XREF.
- Corrected problem where sizing the Cross Reference Window to about two columns was causing a divide by zero GPF.
- Corrected problem where in continuous mode the Append or Insert network was not working properly for the End of Segment.
- Corrected problem when connected with the TCP/IP, and with SA85, if you do a save, it would default the filename as the description name that you had for the TCP/IP address.
- Corrected problem that Cut by Parts was allowed online. This caused the node editor to malfunction and possibly GPF.
- Corrected problem where Import of DOS PGR’s was not bringing in the Headers.
- Corrected problem of Merge not merging the Headers.
- Fixed memory leaks in Status and Powerflow which could have caused a GPF.
- Corrected problem where Import FTK with 1 tag, and Edit the doc gave GPF.
- Corrected problem when trying to import doc of an FMD, it gave error doing shared Doc with object open.
- Corrected in PCOP, where you could not clear Specific IO or Global IO devices above device 2.
- Corrected Loadable screen online: The File Contents always displayed in WORDS and the Current Program showed in BYTES.
- Corrected problem where loadables larger then 50K would cause an overwrite in the configuration code.
- Corrected problem where Compare of loadables did not work online.
- Corrected problem where number nodes of logic used by an EXE loadable was only 1/2 of what it should have used.
- Corrected problem that TCP/IP to Modbus Plus bridge did not work. SGATE bridge software needed to be upgraded. Also a minor change was done to server to communicate to multiple PLC’s better.
- Corrected problem where the Latch Coil attaches the picture for a falling one shot on the cursor.
- Corrected GPF that occurred Online by dropping a Latch coil on top of a regular existing coil, and clicking off of it.
- Corrected problem where changing PLC type from Quantum to A145 caused the TCOP to get mixed up and unable to add modules.
- Corrected problem where import of Doc only, of a PGR, was not bringing in the headers.
- Corrected problem where opening a PGR file and doing print, would give error “Please enter a 0X register range from 1 to 0”.