Features
- Data Window contents can now be printed.
- Addresses can now be forced on and off using the hotkeys Ctrl+F3 and Ctrl+F4, and set on and off using the hotkeys Shift+F3 and Shift+F4.
- The Force Memory data format can now be selected from a drop-down menu.
- Inserting a network no longer automatically places the new network at the top of the screen.
- Users now have the option to automatically insert a new rung when a network is validated.
- Cross Reference now lists Master Control Relay (MCR), Master Control Relay End (MCRE), Go To Subroutine (GTS), and Call Subroutine (SBR) information.
- COM Port availability has now been expanded to 256.
- Communication settings can now be saved and loaded with the program.
- Available S-Memory is now displayed in the Status Bar.
- The Data Window now displays 16-bit binary values as two groups of 8 bits.
- Users are now able to import and export network header information using delimited text files.
Solutions
- Ramp/Soak Flag Addresses now check for valid range correctly.
- The TIWAY Network Access dialog no longer displays a large secondary address when no path descriptions are configured.
- Attempting to Fast Connect via TCP/IP before opening another online connection no longer results in an error.
- Large Special Function Subroutines are now encoded and decoded correctly.
- The PLC Scan Time dialog now properly displays the label “Normal SF Program”.
- Converting TiSoft files to WorkShop now properly retains forced addresses.
- Cross Reference now displays proper usage for Alarm V-Flags, PID V-Flags, and Ramp/Soak Flags.
- Comparing programs containing compiled Special Function Programs or Subroutines to identical contents within a CTI 2500 Series PLC no longer results in a mismatch.
- Long integer addresses are now entered into Special Function parameters correctly.
- The Sentinel Key Driver has been updated to version 7.4 to fully support Windows Vista and other new software.
- All addresses that accept documentation are now valid for cut,copy, and paste commands.
- The Address Documentation Editor now properly parses indirect addresses during copy/paste operations.
- Attempting to generate a Next or Previous Address for Loops or Alarms no longer results in an error.
- Deleting an open Special Function Program or Subroutine that is the last or only window open in WorkShop no longer results in an error.
- The expression parser no longer allows a second assignment operator to be placed in an expression.
- Validated IMATH expression strings now display long hexadecimal values correctly.
- Alarm and Loop variables are now stored and scaled offline correctly.
- Status no longer turns on automatically when entering a new address in the Data Window.
- Pressing the Esc key to cancel a Delete Logic warning message while online no longer results in the logic being deleted.