Features

  • Supports the new CTI 2500 Series processors.
  • Program file passwords are now requested before PLC passwords when attaching online to a PLC.
  • Profibus is now supported when using CTI 2500 PLCs.
  • CAMP is now supported for the local port when using CTI 2500 PLCs. CAMP is supported for the 2572A Ethernet module on CTI 2500 PLCs with Firmware version 2.10. CAMP is supported for the 2572 Ethernet module on CTI 2500 PLCs with Firmware version 8.60.
  • The System Part Number dialog now displays the part number for the CTI 2500 PLC.
  • The PLC Status and Faults dialogs now support new non-fatal errors when using CTI 2500 PLCs.

Solutions

  • FTVersionTrak no longer attempts to connect to the repository when a user opening a WorkShop file that is being tracked by FTVersionTrak cancels the repository connection.
  • Attempting to save a file being tracked by FTVersionTrak to a new filename now results in a disconnection from the repository.
  • Performing a File Program Compare at the Basic level no longer causes WorkShop to close unexpectedly.
  • WorkShop no longer closes unexpectedly when the Activity Audit database file is missing.
  • CTI 2500 programs that have been converted from 505 programs that contained SmarTunes are now downloaded without error.
  • FTVersionTrak will no longer prompt a user to get the latest version of a WorkShop file more than once after the program is opened.
  • Double-clicking an FTVersionTrak-related icon within WorkShop no longer results in the dialog being displayed twice.
  • Site license customers are no longer prompted to enter their password when uninstalling the software.
  • Attempting to launch the full version of FTLogger or FTTrender from within a copy of WorkShop that was originally installed by another user no longer results in an error or the launch of a limited version of the product.
  • Attempting to upgrade the site license of a copy of WorkShop that was originally installed by another user no longer results in an error.
  • Errors occurring within FTVersionTrak no longer cause WorkShop to close unexpectedly.
  • The FTVersionTrak Connect to Repository toolbar button and menu item are no longer active after attaching online to a PLC without a program file.
  • Loading a program file with a large amount of TCP data no longer incorrectly displays an “Address Element is Out of Range” error message.
  • Opening a program file tracked by FTVersionTrak that has been deleted or destroyed in the FTVersionTrak repository now results in a warning message being displayed.
  • Performing a Find on a WAND instruction now correctly displays search results.