Features
- Added option to display inline address documentation in Cross Reference Window.
- Added export and import of Ramp Soak Steps to a text file for use with external editors.
- Added detailed information to the Access Activity Audit records.
- Added export and import of V and K addresses to a text file for use with external editors or transfer to another program.
- Added the ability to copy and paste complete Special Function Programs and Subroutines.
- In the Find dialog the ‘Search Wrap’ check box now retains its last value.
- Added the ability to ‘save by parts’ TCP values from the PLC and ‘load by parts’ to the PLC.
- Added 575 processor indicator (A, B, etc.) in the Status Bar ‘Path’ frame when attached to a 575 processor.
- Added the ability to replace a range of BITS-of-WORD within the replace table.
- Added new FTLogger and FTTrend help files to the install tree.
- Added the ability to delete individual address documentation items from the ‘Edit Documentation’ dialog.
Solutions
- Page information prints can now follow the left and right margins.
- TISOFT read-only files can now be opened in 505 Workshop.
- In NT Security the user name given by the operating system is now the user name displayed in the Activity Audits.
- The Special Function Compare mismatches are stated more clearly and identify the line numbers that do not match. The comparison will continue until the maximum number of mismatches is found.
- Corrected problem reading the enabled/disabled and compiled/not compiled Special Functions setting from a TISOFT file.
- Corrected problem within the Data window using the Fill dialog on a 575 PLC.
- The Tag and Description is now displayed for register addresses with leading ‘@’.
- The Tag and Description is now copied with SBR and GTS instructions.
- The edit boxes within the documentation window can now accommodate longer addresses (i.e. VMM123456).
- Corrected problem when launching 505 WorkShop by double-clicking a program file.
- Format of rung comments and descriptions is now consisting upon loading from TISOFT and then exporting back to TISOFT.
- Deleting a Special Functions Program line online will flag the special function save requirements.
- Changes to Program Setup will flag the Program Setup save requirement.
- Clarified wording in the Program Setup – Change Colors: ‘Status Foreground’ is now ‘Status: Instruction Foreground’, ‘Status Optimize Foreground’ is now to ‘Status: Value Foreground’.
- The print settings are now saved in the registry when pressing the ‘set as default’ button. These settings are then used in a new program and when ‘Restore Defaults’ is used.
- The ‘Find’ dialog will now inform the user if an illegal search address has been entered.
- ‘IP Port’in the TCP/IP communications setup dialog has been changed to ‘TCP Port.’
- Corrected problem with the Data Window going blank when canceling a close program command.
- Corrected problem with TIWAY ladder status.
- Profibus slaves are now cleared before downloading new program to PLC.
- Corrected entering ranges above the configured limit for SBR or GTS address within the replace dialog.
- Improved dialog message regarding the Cross Reference table not being up to date.
- Corrected misleading error when message with the ‘Unique Address’ feature.
- Corrected the error checking for RLL instructions using the DSP register address.